LCDWAIT=0, CPSEL=0, ALTDIV=0, LCDSTP=0, FDCIEN=0, HREFSEL=0, SOURCE=0, RVEN=0, LCDIEN=0, DUTY=000, LCDEN=0, VSUPPLY=00
LCD general control register
DUTY | LCD duty select 0 (000): Use 1 BP (1/1 duty cycle). 1 (001): Use 2 BP (1/2 duty cycle). 2 (010): Use 3 BP (1/3 duty cycle). 3 (011): Use 4 BP (1/4 duty cycle). (Default) 4 (100): Use 5 BP (1/5 duty cycle). 5 (101): Use 6 BP (1/6 duty cycle). 6 (110): Use 7 BP (1/7 duty cycle). 7 (111): Use 8 BP (1/8 duty cycle). |
LCLK | LCD clock prescaler |
SOURCE | LCD clock source select 0 (0): Selects the default clock as the LCD clock source. 1 (1): Selects the alternate clock as the LCD clock source. |
LCDEN | LCD driver enable 0 (0): All frontplane and backplane pins are disabled. The LCD controller system is also disabled, and all LCD waveform generation clocks are stopped. VLL3 is connected to VDD internally. 1 (1): LCD controller driver system is enabled, and frontplane and backplane waveforms are generated. All LCD pins, LCD_Pn, enabled using the LCD pin enable register, output an LCD driver waveform.The backplane pins output an LCD driver backplane waveform based on the settings of DUTY[2:0]. Charge pump or resistor bias is enabled. |
LCDSTP | LCD driver, charge pump, resistor bias network, and voltage regulator while in Stop mode. 0 (0): Allows the LCD driver, charge pump, resistor bias network, and voltage regulator to continue running during Stop mode. 1 (1): Disables the LCD driver, charge pump, resistor bias network, and voltage regulator when MCU goes into Stop mode. |
LCDWAIT | LCD driver, charge pump, resistor bias network, and voltage regulator stop while in Wait mode. 0 (0): Allows the LCD driver, charge pump, resistor bias network, and voltage regulator to continue running during Wait mode. 1 (1): Disables the LCD driver, charge pump, resistor bias network, and voltage regulator when MCU goes into Wait mode. |
ALTDIV | LCD alternate clock divider 0 (0): Divide factor = 1 (No divide) 1 (1): Divide factor = 8 |
FDCIEN | LCD fault detection complete interrupt enable 0 (0): No interrupt request is generated by this event. 1 (1): When a fault is detected and FDCF bit is set, this event causes an interrupt request. |
LCDIEN | LCD frame frequency interrupt enable 0 (0): No interrupt request is generated by this event. 1 (1): When LCDIF bit is set, this event causes an interrupt request. |
VSUPPLY | Voltage supply control 0 (00): Drive VLL2 internally from VDD. 1 (01): Drive VLL3 internally from VDD. 3 (11): Drive VLL3 externally from VDD or drive VLL1 internally from VIREG. |
LADJ | Load adjust |
HREFSEL | High reference select 0 (0): Divide input, VIREG = 1.0 V for 3 V glass. 1 (1): Do not divide the input, VIREG = 1.67 V for 5 V glass. |
CPSEL | Charge pump or resistor bias select 0 (0): LCD charge pump is disabled. Resistor network selected. (The internal 1/3-bias is forced.) 1 (1): LCD charge pump is selected. Resistor network disabled. (The internal 1/3-bias is forced.) |
RVTRIM | Regulated voltage trim |
RVEN | Regulated voltage enable 0 (0): Regulated voltage disabled. 1 (1): Regulated voltage enabled. |